GE Healthcare · MRDiscovery22688732267600
Fails TPS Reset when booting up to Applications or when Resetting TPS Due to Scan Room Power Supply breaker tripped.
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2268873 The home and end of travel switches are not detected Mon Sep 21 14:46:30 2009 Error: 2268873 Host: LIBR-MR1 Process: NSP File: SCP:SriManager Line: 3800 Exception Class: Unknown Severity: Unkn 2268873 The home and end of travel switches are not detected. 2267600 - The IRF3 detected a fault on the fiber links. Status register See Long Description Error: 2267600 Host: LIBR-MR1 Process: NSP File: AGP:Irf3RrfHWO Line: 1418 Exception Class: Unknown Severity: Unknown The IRF3 detected a fault on the fiber links. Status register=0x%X The modules connected to these IRF3 jacks were determined to be the cause of the disruption: %s Extended Error: A momentary problem with any module connected to the DVMR dual fiber links can bring the links down for every node. The IRF3 can detect which link was the first to drop out. The module connected to that link should be the one who initiated the problem. If several modules dropped out at the same time the IRF3 will report multiple modules. In this case there might be a single problem effecting multiple modules such as a power supply glitch or a drop out on the shared reference clock source. Note: a problem on the RRX to ICN links will cause t
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.