Scan Aborts with EOS Error due to defective SFP module.
Symptom
Scan Aborts with EOS Error Openspeed system running HFO3 M4. When customer uses the frfse-rpc PSD (intermittently) they will only get half the images reconstructed (only odds). This is because the scan has aborted. Then when they try to download the next series the TPS hangs and the customer has to reset TPS or reboot the system. Operator sees the message "Pulse Sequence Error Occurred". Message log has EOS and other errors logged. See attachments for the review screens and errors logged during these events. MRIhc02494 Openspeed system running HFO3 M4. When customer uses the frfse-rpc PSD (intermittently) they will only get half the images reconstructed (only odds). This is because the scan has aborted. Then when they try to download the next series the TPS hangs and the customer has to reset TPS or reboot the system. Operator sees the message "Pulse Sequence Error Occurred". Message log has EOS and other errors logged. See attachments for the review screens and errors logged during these events. MRIhc02494
Error message
2252713 PSD programming error. Pulse generation was still active when an SSP EOS was received Wed Sep 5 10:09:30 2007 Error: 2252713 Host: EMR1 Process: NSP File: AGP:seq_cntl.c Line: 671 PSD programming error. Pulse generation was still active when an SSP EOS was received. 2218537 Scan stopped, Scan Stopped due to error : PSD programming error. Pulse generation was still active when an SSP EOS was received Sat Nov 1 08:42:22 2008 2218537 1 lx-mr scn MsaScanMgr.m 2852 Scan stopped, Scan Stopped due to error : PSD programming error. Pulse generation was still active when an SSP EOS was received..
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- DV22.0 For the Discovery MR750, MR450 or Optima MR450w products only. For the Discovery MR750, MR450 or Optima MR450w products only.
- Component
- 5183329-2 Fiber Optic Transceiver SFP 4Gb Multimode, RoHS-Compliant Note, as of March 24, 2010 this part can not be ordered yet. It will be a FRU. If you cant order the transceiver order the higher FRU.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.