TPS reset fails and each gradient axis reports power off fault due to 48V power supply breaker tripped.
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2267946 The Y-Axis XPS is reporting a power off fault. Check EMO reset See Long Description Error: 2267946 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The Y-Axis XPS is reporting a power off fault. Check EMO reset.-> Extended Error: Ensure that the 48V input power cable is connected to the corresponding XPS. Ensure that the Octavius (Ethernet type) cable is connected to the corresponding XPS. Swap Octavius cables between axis and observe if fault follows the XPS. If fault follows the XPS, replace the XPS. If fault does not follow the XPS replace the GMC. 2267944 The Z-Axis XPS is reporting a power off fault. Check EMO reset. See Long Description Error: 2267944 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The Z-Axis XPS is reporting a power off fault. Check EMO reset.-> Extended Error: Ensure that the 48V input power cable is connected to the corresponding XPS. Ensure that the Octavius (Ethernet type) cable is connected to the corresponding XPS.
Applies to
- Models
- Optima
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- DV22.0 For the Discovery MR750, MR450 or Optima MR450w products only. For the Discovery MR750, MR450 or Optima MR450w products only.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.