GE Healthcare · MRDiscovery2254683218652726225272675822688361540201
Cradle motion errors during scanning and having to press advance to scan several times to advance cradle to proper posit…
Cradle motion errors during scanning and having to press advance to scan several times to advance cradle to proper position due to SRI4.
Symptom
Cradle motion errors during scanning and having to press advance to scan several times to advance cradle to proper position Cradle motion errors during scanning and having to press advance to scan several times to advance cradle to proper position.
Error message
2254683 Diagnostic SRI Motion Test SRI Diagnostic Cradle Move Failed see long 2254683 diagCoord SriCanHWO 4246 Diagnostic: SRI Motion Test Iteration: 1 of 1 Action: 1 Task ID: 0xf29ab50 Time: 21865 Object: SCP Test Task Function: Software/Firmware/Config: N/A SRI Diagnostic Cradle Move Failed Target Position: 2726225 um Actual Position: 2726758 um- 2268836 Cradle move failed to reach target position within position tolerance. Error: 2268836 Host: lx-mr Process: NSP File: SCP:LongMotionMonit Line: 2095 Exception Class: Unknown Severity: Unknown Function: Patient Handling: Control/Display PSD: FSE-XL Coil: HNS Head Scan: 2649/9 Cradle move failed to reach target position within position tolerance Target: 1540201 um Acutal: 1531771 um Tolerance: 500 um 2268819 Velocity tolerance exceeded Mon Jan 18 08:45:10 2010 Error: 2268819 Host: LIBR-MR1 Process: NSP File: SCP:LongMotionMonit Line: 1995 Exception Class: Unknown Severity: Unknown Function: Patient Handling: Control/DisplayPSD: fsespt Coil: BODY Scan: 50782/1Velocity tolerance exceeded.Expected: 100000um/sActual: 16600um/s
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
- Component
- 5160929 SRI4 with Remote Intercom Board 3 5160929 SRI4 with Remote Intercom Board 3.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.