Scanner Hardware Stopped Scan.
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260118224 60-0403 mA out of range See Long Description for complete error Thu Jun 9 14:36:46 2005 260118224 orp orp_subsys gen_exec.c 2150 Host : Jedi Exception Class : Soft Severity : Pri/Soft File : gen_exec.c Line# : 2150 Function : No System Function Reported Scan Type : Helical Scan: 10105/2/5 (60-0403)mA out of range Measured mA every 50 msec exceeded 5 percent of mA demand.This error is logged, but does not stop the exposure. Z6,Z7= 0h,0h Note: MA Out Of Range (60-0403) error may be bogus depending on mA scanning mode. If this error occurs during a Helical AutomA scan, please ignore. Jedi Error # 260118224 (60-0403) “Measured mA every 50 msec exceeded 5 percent of mA demand” is an informational message intended to identify a possible mA stability issue. This error is logged but does not stop the exposure. If this error happens during a fixed mA scan it could indicate a problem and should be investigated further. But, if this error occurs during a helical with automA, this error should be ignored. In the automA mode, the mA is constantly changing and therefore this message does not indicate a real problem. Source of this information is as follows: Thanks to Jonathan Sc
Applies to
- Models
- Discovery
- Product
- Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5332530 SC-Fast KV HV Tank for Discovery HD- Use after option upgrade ONLY See long description for details Part #: 5332530 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: SC-Fast KV HV Tank FRU: Yes Status: Orderable Comments: ** FE ASSIST ** Be sure you have SW version 09MW29.14. If you have SW version 08MW39.4 then you must order 5173970-2 SC HIGH VOLTAGE TANK. (212001147 010510) *** 2ND OPINION NOTES *** As of 02/11/10 Call Engineering Contact John Breunissen - 414-202-9485 or Daniel Nunez - 414-721-8460 Before ordering. Also, perform: Meter verification, No load test with/without tube, Focal spot diagnostics(with/without kV), and Filament heating diagnostic. If any of these tests fail without tube connected, replace the tank and redo the tests. Per HDVCT Options RSPL, 212008898, 5/4/09. 2ND OPINION NOTES *** Before ordering HV Tank perform: Meter verification, No load test with/without tube, Focal spot diagnostics(with/without kV), and Filament heating diagnostic. If any of these tests fail without tube connected, replace the tank and redo the tests.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required