Unable to Scan with XGA and XPS reporting a power off fault for each Axis due to PS2 48 Volt 1000W Power Supply in PDU.
Symptom
Unable to Scan with XGA and XPS reporting a power off fault for each Axis See Long Description System intermittently stops and only way to recover is by rebooting system.These errors seen in log when interruption occurs: Mon Nov 30 10:26:41 2009 Error: 2267943 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The Z-Axis XGA is reporting a power off fault. Check EMO reset.-> Mon Nov 30 10:26:41 2009 Error: 2267944 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The Z-Axis XPS is reporting a power off fault. Check EMO reset.-> Mon Nov 30 10:26:42 2009 Error: 2267945 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The Y-Axis XGA is reporting a power off fault. Check EMO reset.-> Mon Nov 30 10:26:42 2009 Error: 2267946 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The Y-Axis XPS is reporting a power off fault. Check EMO reset.-> Mon Nov 30 10:26:43 2009 Error: 2267947 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The X-Axis XGA is reporting a power off fault. Check EMO reset.-> Mon Nov 30 10:26:43 2009 Error: 2267948 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The X-Axis XPS is reporting a power off fault. Check EMO reset.->
Error message
2267943 The Z-Axis XGA is reporting a power off fault. Check EMO reset. See Long Description Error: 2267943 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The Z-Axis XGA is reporting a power off fault. Check EMO reset.-> Extended Error: Ensure that the 48V input power cable is connected to the corresponding XGA. Ensure that the Octavius (Ethernet type) cable is connected to the corresponding XGA. Swap Octavius cables between axis and observe if fault follows the XGA. If fault follows the XGA, replace the XGA. If fault does not follow the XGA replace the GMC. 2267948 The X-Axis XPS is reporting a power off fault. Check EMO reset.-> See Long Description Error: 2267948 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The X-Axis XPS is reporting a power off fault. Check EMO reset.-> Extended Error: Ensure that the 48V input power cable is connected to the corresponding XPS. Ensure that the Octavius (Ethernet type) cable is connected to the corresponding X
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
- Component
- 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109. Part is being set up for 3.0T DVMR program RSPL. 501139061, 5-Mar-08.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.