Explanation of 2267873 The % axis XGA-SB is reporting a TEC out of temperature range fault Due to XGD Amplifier. 2267873…
Explanation of 2267873 The % axis XGA-SB is reporting a TEC out of temperature range fault Due to XGD Amplifier. 2267873 in error log with no apparent effect on scanner operation.
Symptom
2267873 in error log with no apparent effect on scanner operation See Long Description One axis is reporting this error, but it does not seem to affect scanning. 2267873 Host: C-3TMRI2 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 The Y axis XGA-SB is reporting a TEC out of temperature range fault. The TEC temperature is 124C.-> Extended Error: A thermo-electric device (TEC) is present on the internal system board of the XGA to control the temperature stability of critical compensation circuits. The TEC can become dislodged or malfunction thus causing this error. The TEC can only compensate (by adding heat) within a certain temperature range of the XGA cold-plate. Please first confirm that the PE cooling loop of the HEC is stable and operating in the specified range (30-35 C). TEC is not serviceable. The XGA will operate without temperature stable TEC, however, a consequence is that FMRI scans may exhibit ghosting artifact. If HEC PE cooling loop OK then please schedule time with customer to replace XGA at next earliest convenience or during next scheduled maintenance.
Error message
2267873 The Y axis XGA-SB is reporting a TEC out of temperature range fault. The TEC temperature is 124C.
Applies to
- Models
- Optima
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- DV22.0 For the Discovery MR750, MR450 or Optima MR450w products only. For the Discovery MR750, MR450 or Optima MR450w products only.
- Component
- 5184566-2 XGD AMPLIFIER 5184566-2 XGD AMPLIFIER
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.