MR000102 PDS - HEC Alert - Defective Facility Return Pressure Sensor Detected due to Defective Sensor.MR000102 PDS - HEC…
MR000102 PDS - HEC Alert - Defective Facility Return Pressure Sensor Detected due to Defective Sensor.MR000102 PDS - HEC Alert - Defective Facility Return Pressure Sensor Detected.
Symptom
MR000102 PDS - HEC Alert - Defective Facility Return Pressure Sensor Detected. Reading Equals Zero. MR000102 - Two consecutive sample windows contain 0 values for return pressure between XXXXXX and XXXXXX. Possible defective cust return pressure sensor. NOTE: The OnWatch Informatics Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive service.
Error message
MR000102 PDS - HEC Alert - Defective Facility Return Pressure Sensor Detected. Reading Equals Zero. Select this Error only when handling MR000102 PDS Issue Concept. NOTE: The OnWatch Informatics Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive service.
Applies to
- Models
- Discovery, Optima
- Product
- Discovery MR450 Also called DVMR. This product is compatible with 1.5T 20.1, 20.1_IB1, IB2, 21.0 and DV22.0 software systems only.
- Software
- 20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
- Component
- 5267643 Liquid Pressure Sensor Kit 5267643 Liquid Pressure Sensor Kit
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.