Unable to Scan with Safemode Startup of XGD Failed for each Axis due to PS2 48 Volt 1000W Power Supply inside PDU.
Symptom
Unable to Scan with Safemode Startup of XGD Failed for each Axis See Long Description Unable to scan with errors logged "Safemode Startup of XGD Failed" for every gradient axis seen at same time in error log. See errors, below. Notice that the date/time is the same for each error, and that all axes are reporting the error: X, Y & Z. Fri Mar 27 11:31:06 2009 Error: 2267798 Host: GEMR3T Process: NSP File: SCP:GradientHwo Line: 1907 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 Safe mode startup of the XGD (XGA-SB X axis) failed. Check EMO reset and perform a TPS reset. If this error occurs again, contact your service representative .-> Fri Mar 27 11:31:06 2009 Error: 2267801 Host: GEMR3T Process: NSP File: SCP:GradientHwo Line: 1907 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 Safe mode startup of the XGD (XGA-SB Y axis) failed. Check EMO reset and perform a TPS reset. If this error occurs again, contact your service representative .-> Fri Mar 27 11:31:06 2009 Error: 2267804 Host: GEMR3T Process: NSP File: SCP:GradientHwo Line: 1907 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 Safe mode startup of the XGD (XGA-SB Z axis) failed. Check EMO reset and perform a TPS reset. If this error occurs again, contact your service representative .-> Fri Mar 27 11:31:06 2009 Error: 2267807 Host: GEMR3T Process: NSP File: SCP:GradientHwo Line: 1907 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 Safe mode startup of the XGD (XPS-SB X axis) failed. Check EMO reset and perform a TPS reset. If this error occurs again, contact your service representative .-> Fri Mar 27 11:31:06 2009 Error: 2267810 Host: GEMR3T Process: NSP File: SCP:GradientHwo Line: 1907 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 Safe mode startup of the XGD (XPS-SB Y axis) failed. Check EMO reset and perform a TPS reset. If this error occurs again, contact your service representative .-> Fri Mar 27 11:31:06 2009 Error: 2267813 Host: GEMR3T Process: NSP File: SCP:GradientHwo Line: 1907 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 Safe mode startup of the XGD (XPS-SB Z axis) failed. Check EMO reset and perform a TPS reset. If this error occurs again, contact your service representative .->
Error message
2267813 Safe mode startup of the XGD (XPS-SB Z axis) failed. Check EMO reset and perform a TPS reset. See Long Description 2267813 "Safe mode startup of the XGD (XPS-SB Z axis) failed.\n\ Check EMO reset and perform a TPS reset. If this error occurs again, contact your service representative.->" 2267810 Safe mode startup of the XGD (XPS-SB Y axis) failed. Check EMO reset and perform a TPS reset. See Long Description 2267810 "Safe mode startup of the XGD (XPS-SB Y axis) failed. Check EMO reset and perform a TPS reset. If this error occurs again, contact your service representative.->" 2267807 Safe mode startup of the XGD (XPS-SB X axis) failed. Check EMO reset and perform a TPS reset. See Long Description 2267807 "Safe mode startup of the XGD (XPS-SB X axis) failed. Check EMO reset and perform a TPS reset. If this error occurs again, contact your service representative.->"
Applies to
- Models
- Optima
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- 21.0 Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750). Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750).
- Component
- 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109. Part is being set up for 3.0T DVMR program RSPL. 501139061, 5-Mar-08.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- IApplication Software does not complete the boot process with TPS Download failure Due to Idle Overnight With Power On.
- CWA ID107471. Unable to Download or Reset The TPS MGD or ISE.