Unable to scan with XG errors

Error message

Error: 186218 detail error code : 60 - 0313H Exposure error : ILR max current detected See long description for complete error Thu Aug 25 08:58:14 2005 Error: 186218 Host: CTO1_OC0 Process: tgp_out File: tgp_in_input.c Line: 334 XG Error phase is 4 code is 60. detail error code : 60 - 0313H Exposure error : ILR max current detected

Error: 186218 Tube Spits error : Spit retry failed detail error code : 60 - 0321H See Long Description for full error Wed Mar 5 07:54:17 2008 Error: 186218 Host: CTSIM Process: tgp_out File: tgp_in_input.c Line: 334 XG Error phase is 5 code is 60. detail error code : 60 - 0321H Tube Spits error : Spit retry failed (spit TD computing error)

Applies to

Product
CT/e, CT Prospeed AI/FI Irix or Linux See long description for sale information Product Name: CT/e Single CT Scanner: Irix Platform A list of types. (a Product/hardware table) N/A An On-site / Remote identification aid . (Example: check_config) N/A A Table of options (included, optional, new introductions, …) N/A A list of Software that has run on this product (Product / Software Compatibility Table) 3.01 / 3.02 / 3.03 Linux CTe Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found in the attachment Always use the most appropriate documentation for your system.
Component
D3161T / D3162T Venus tube used on CTE (D3161T is NEW non reload version) See Long Description for details X-ray tube D3162T / D3161T , Modified Venus tube Part #: D3162T Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MX135 CT TH.1.1 RELOAD FRU: Yes Status: Orderable Comments: FLS - ECONOMY SLIP RING CT TUBE (ALSO CALLED CTE HIGHSPEED) 23 OHM (STATOR RESISTOR VALUE) 11/24/99 AM SOURCE = MEXICO FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA Part #: D3161T Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MX135 CT TH.1.1 GREEN FRU: Yes Status: Orderable Comments: This is GREEN tube, order only if New is required , If not please SEE D3162T, ms13452