Unable to Scan with XGA and XPS reporting a power off fault for each Axis due to PS2 48 Volt 1000W Power Supply in PDU
Symptom
Unable to Scan with XGA and XPS reporting a power off fault for each Axis See Long Description System intermittently stops and only way to recover is by rebooting system.These errors seen in log when interruption occurs: Mon Nov 30 10:26:41 2009 Error: 2267943 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The Z-Axis XGA is reporting a power off fault. Check EMO reset.-> Mon Nov 30 10:26:41 2009 Error: 2267944 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The Z-Axis XPS is reporting a power off fault. Check EMO reset.-> Mon Nov 30 10:26:42 2009 Error: 2267945 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The Y-Axis XGA is reporting a power off fault. Check EMO reset.-> Mon Nov 30 10:26:42 2009 Error: 2267946 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The Y-Axis XPS is reporting a power off fault. Check EMO reset.-> Mon Nov 30 10:26:43 2009 Error: 2267947 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The X-Axis XGA is reporting a power off fault. Check EMO reset.-> Mon Nov 30 10:26:43 2009 Error: 2267948 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The X-Axis XPS is reporting a power off fault. Check EMO reset.->
Error message
2267948 The X-Axis XPS is reporting a power off fault. Check EMO reset.-> See Long Description Error: 2267948 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The X-Axis XPS is reporting a power off fault. Check EMO reset.-> Extended Error: Ensure that the 48V input power cable is connected to the corresponding XPS. Ensure that the Octavius (Ethernet type) cable is connected to the corresponding XPS. Swap Octavius cables between axis and observe if fault follows the XPS. If fault follows the XPS, replace the XPS. If fault does not follow the XPS replace the GMC. 2267947 The X-Axis XGA is reporting a power off fault. Check EMO reset. See Long Description Error: 2267947 Host: RCMR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: T1flair Coil: 8HRBRAIN Scan: 1502/13 The X-Axis XGA is reporting a power off fault. Check EMO reset.-> Extended Error: Ensure that the 48V input power cable is connected to the corresponding XGA. Ensure that the Octavius (Ethernet type) cable is connected to the corresponding X
Applies to
- Models
- Optima
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- DV22.0 For the Discovery MR750, MR450 or Optima MR450w products only. For the Discovery MR750, MR450 or Optima MR450w products only.
- Component
- 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109. Part is being set up for 3.0T DVMR program RSPL. 501139061, 5-Mar-08.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- IApplication Software does not complete the boot process with TPS Download failure Due to Idle Overnight With Power On.
- CWA ID107471. Unable to Download or Reset The TPS MGD or ISE.