The Customer complains of a Water or a fluid leak on the system.
Symptom
The Customer complains of a Water or a fluid leak on the system. The customer indicates there is water leaking from the closed loop cooling system. Fluid is coming out of the tube arm assembly or in the technical room. If zero stock on 2184070-2 RP ROTATING JOINT then order 2129844-2 RIGID WATER COOLING ASSEMBLY and it contain the joint part. Also replace the two O-rings with new or they will leak next. The Customer complains of a Water or a fluid leak on the system. The customer indicates there is water leaking from the closed loop cooling system. Fluid is coming out of the tube arm assembly or in the technical room. 2184070-2 RP ROTATING JOINT then order 2129844-2 RIGID WATER COOLING ASSEMBLY and it contain the joint part. Also replace the two O-rings with new or they will leak next
Error message
IN2K, Advantx, 41B4, 42FB, 30068:Tube casing water flow not detected IN2K, Advantx, 41B4, 42FB, 30068:Tube casing water flow not detected: This error does not inhibit Xrays. If the water flow issue is not address, the XRT could overheat enough to open the >70 degree C switch on the XRT, the error 42FB is then generated and time has to be allowed for the XRT to cool. Error 30068 is generated on an Innova 2000 system. IN2K, Advantx 41B4, 42FB, 30068: Tube casing water flow not detected: This error does not inhibit Xrays. If the water flow issue is not address, the XRT could overheat enough to open the >70 degree C switch on the XRT, the error 42FB is then generated and time has to be allowed for the XRT to cool. Error 30068 is generated on an Innova 2000 system.
Applies to
- Models
- Advantx
- Product
- Advantx E Biplane Advantx E biplane systems: LCLP+ (22 cm II), LCN+ (32 cm II), LCALP+ (40 cm frontal plane, 32 cm lateral plane) Advantx E biplane systems: LCLP+ (22 cm II), LCN+ (32 cm II), LCALP+ (40 cm frontal plane, 32 cm lateral plane)
- Component
- 5332506FRU Kit Swivel Elbow-V2 + Water Hose 5332506FRU Kit Swivel Elbow-V2 + Water Hose 5332506FRU Kit Swivel Elbow-V2 + Water Hose May also need the following parts for systems with MX150 tubes: 5318104:QUICK DISCONNECT ADAPTER - FEMALE ST 5357454:FRU Adaptator for Advtx-e Tube water 212009270 02/01/2011 11:45 GMT
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.
- Intermittent Gantry Lockup usually occurred when bagging the Detector or Removing the patient from the table.
- Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.
- Omega, Can not move the table top in the lateral direction.
- The Advantx Console is Blank on boot of the system.
- Exabyte won't archive or eject