What are the Troubleshooting Steps When Error 2267955 or 2267950 Logged, Usually Along With Another Gradient Error Messa…

What are the Troubleshooting Steps When Error 2267955 or 2267950 Logged, Usually Along With Another Gradient Error Message.

Symptom

What are the Troubleshooting Steps When Error 2267955 or 2267950 Logged, Usually Along With Another Gradient Error Message See Long Description One of these messages seen in system error log, usually in company of another gradient error message. What are the troubleshooting steps to take in this situation? Error: 2267955 Host: A_3_0T Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 The X-Axis XPS is reporting a FPGA fault.-> Extended Error: Ensure that the Octavius (Ethernet type) cable is connected to the XPS. Observe that the XPS heart-beat LED is flashing. If the heart-beat LED is not flashing ensure that the 48V cable is plugged in. If power is connected and no heart-beat replace the XPS. ----- or ------ Error: 2267950 Host: BUMMRMRM003 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 The Z-Axis XGA is reporting a FPGA fault.-> Extended Error: Ensure that the Octavius (Ethernet type) cable is connected to the XGA. Observe that the XGA heart-beat LED is flashing. If the heart-beat LED is not flashing ensure that the 48V cable is plugged in. If power is connected and no heart-beat replace the XGA.

Error message

2267955 The X-Axis XPS is reporting a FPGA fault. See Long Description Error: 2267955 Host: A_3_0T Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 The X-Axis XPS is reporting a FPGA fault.-> Extended Error: Ensure that the Octavius (Ethernet type) cable is connected to the XPS. Observe that the XPS heart-beat LED is flashing. If the heart-beat LED is not flashing ensure that the 48V cable is plugged in. If power is connected and no heart-beat replace the XPS.

2267950 The Z-Axis XGA is reporting a FPGA fault. See Long Description Error: 2267950 Host: BUMMRMRM003 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 The Z-Axis XGA is reporting a FPGA fault.-> Extended Error : Ensure that the Octavius (Ethernet type) cable is connected to the XGA. Observe that the XGA heart-beat LED is flashing. If the heart-beat LED is not flashing ensure that the 48V cable is plugged in. If power is connected and no heart-beat replace the XGA.

Applies to

Models
Discovery
Product
Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
Software
20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.