GE Healthcare · MRDiscovery2274035
2274035 Coil Fault Open Circuit A multicoil bias fault was detected while scanning due to 32 Channel Head Coil.
Symptom
Unable to Scan with Multicoil Bias Fault Detected Open Circuit See Long Description (See below for a copy of the logged error from the site). This doesn't happen with any other coil. Fri Feb 1 09:19:23 2008 Error: 2252301 Host: lgmc-lxmr2 Process: NSP File: SCP:DCB Line: 920 Multicoil Bias Fault Detected - Open Circuit. Try re-seating all coil connectors. MCD2 Channel 1 of 16, counting from 1 Value: 0 mA Limit: 98 mA Mask of failed channels: 0x1 Ch 1-8 : Legacy MC Conn Ch 17-24 : Conn A Ch 25-32 : Conn B->
Error message
2274035 Coil Fault Open Circuit multicoil bias fault was detected while scanning Connector see long Error: 2274035 Host: THDMRI03 Process: NSP File: SCP:RfHubCanHWO::RfBias Line: 4080 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: T2flair Coil: 32Ch Head Scan: 276/5 Coil Fault - Open Circuit A multicoil bias fault was detected while scanning. Reseat all coils and check coil connections. Connector: Port 1 (P1) Channels faulted: 0x20 First channel: 6 of 32, counting from 1 Fault value: 7943 mV, Channel: 6->
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
- Component
- 5329833 MRII 32 Channel Head Coil 5329833 MRII 32 Channel Head Coil
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.