GE Healthcare · MRDiscovery227002822700292270024
Fails TPS Reset when booting up to Applications or when Resetting TPS due to NB Exciter Module.
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2270028 VRF - Error bit(s) activated in RRX Status Register 2 (0x00F8 Error: 2270028 Host: MOI_MR Process: LxMxConsumer File: VrfTrace.cpp Line: 80 Server Name: ADS1 VRF - Error bit(s) activated in RRX Status Register 2 (0x00F8). The VRF is located at ICN1(ICN2), if ADS(ADS1) reports this error. VRF ID: 0x0 RRX Status Register 2: 0x8000000000000000 2270029 VRF CLOCK is not present or is not working properly Error: 2270029 Host: MOI_MR Process: LxMxConsumer File: VrfTrace.cpp Line: 80 Server Name: ADS1 VRF CLOCK is not present or is not working properly. The VRF is located at ICN1(ICN2), if ADS(ADS1) reports this error. VRF Register: 0x0 Descriptions: 0x150-> 2270024 Server Name ADS1 VRF Error bit(s) activated in Control Status Register (0x0000) see long Error 2270024 4 goc LxMxConsumer VrfTrace.cpp 80 Server Name: ADS1 VRF - Error bit(s) activated in Control Status Register (0x0000). The VRF is located at ICN1(ICN2), if ADS(ADS1) reports this error. VRF ID: 0x0 Control Status Register: 0x150-> Extended Error: Check dual fiber optic data cable connection to VRF. Run Clock status and link status from VRF status display in the diagnostics. Check power to RRX module in scan room. The
Applies to
- Models
- Discovery
- Product
- Discovery MR450 Also called DVMR. This product is compatible with 1.5T 20.1, 20.1_IB1, IB2, 21.0 and DV22.0 software systems only.
- Software
- 20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
- Component
- 5154662 1.5T Reference Clock and HDv NB exciter Module 5154662 1.5T Reference Clock and HDv NB exciter Module.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.