Pular para o conteúdo principal
GE Healthcare · MRDiscovery226788522678272267892

2267885 The Z axis XPS is reporting a PLL Warning Due to XGD Power Supply.

Symptom

Will Not Scan with Gradient Errors.

Error message

2267885 The % axis XPS is reporting a PLL Warning See Long Description Error: 2267885 Host: signa2 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 The % axis XPS is reporting a PLL Warning.-> Extended Error: Ensure the fiber optic cable J4 is connected to the corresponding XPS, and that light is present. Check that the corresponding channel on the XPS-CB in the Cronus chassis has a good fiber optic output.

2267827 XGD hardware warning detected. The PLL_FAULT_9510 bit in SIGNAL_BRD_FLTS register was detected on the XGD XPS-SB board % axis 2267827 XGD hardware warning detected. The PLL_FAULT_9510 bit in SIGNAL_BRD_FLTS register was detected on the XGD XPS-SB board % axis.

2267892 The % axis XPS is reporting an Int4_Lock Fault. This is normal during a TPS Reset, but should not occur during scan-time See Long Description 2267892 MOI_MR NSP SCP:FspMac.cpp 320 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: FSE-XL Coil: HNS CTL456 Scan: 129/7 The % axis XPS is reporting an Int4_Lock Fault. This is normal during a TPS Reset, but should not occur during scan-time.

Applies to

Models
Discovery
Product
Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
Software
20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
Component
5148804-2 XGD Power Supply XPS 5148804-2 XGD Power Supply XPS ** 2nd Opinion Part ** Confirm appropriate extended error messages have been read and gradient diagnostics have been executed before placing order for this part. 212002950 May 28, 2009. Promoted this part for DVMR 3.0T NPI program, 212035293, 10 April 2008.
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare MR issues