2267910 Power cabinet reporting 48V undervoltage due to 48 V supply in PDU.
Symptom
Gradient Fidelity Diagnostic Error 2267910 The Power Cabinet AUX board is reporting a 48V undervoltage (or overvoltage) See Long Description This error seen when pulsing gradients, running gradient fidelity diagnostic: Fri Apr 10 02:02:51 2009 Error: 2267910 Host: RIC_HDMR2 Process: diagCoord File: FspMac.cpp Line: 320 Diagnostic: Average Forward Power Measurement Circuit Test Iteration: 1 of infinite Action: 1 Task ID: 0x2548ba0 Time: 3996792 Object: SCP Function: Gradient: N/A The Power Cabinet AUX board is reporting a 48V undervoltage (or overvoltage) . Message will state either undervoltage or overvoltage but not both at same time.
Error message
2267910 The Power Cabinet AUX board is reporting a 48V undervoltage See Long Description Error: 2267910 Host: RIC_HDMR2 Process: diagCoord File: FspMac.cpp Line: 320 Diagnostic: Average Forward Power Measurement Circuit Test Iteration: 1 of infinite Action: 1 Task ID: 0x2548ba0 Time: 3996792 Object: SCP Function: Gradient: N/A The Power Cabinet AUX board is reporting a 48V undervoltage.
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
- Component
- 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109. Part is being set up for 3.0T DVMR program RSPL. 501139061, 5-Mar-08.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.