Scanner Hardware Stopped Scan with High Voltage errors
Symptom
Scanner Hardware Stopped Scan with High Voltage errors
Error message
Error: 260118213 (60-0316) Spit Max error. PPC board has detected the number of tube spits during exposure has reached the limit See Long Description for two error examples Sat Dec 17 18:32:18 2005 Error: 260118213 Host: orp Process: orp_subsys File: gen_exec.c Line: 2150 Sat Dec 17 18:32:17 2005 Host : Jedi Ermes # : 260118213 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2150 Function : No System Function Reported Scan Type : Axial Scan: 10153/2/2 (60-0316)Spit Max error. PPC board has detected the number of tube spits during exposure has reached the limit (see theory of operation, software section).^C Z6,Z7= ch,0h Error: 260118212 ( 60-0314 ) ILR Current time out. The current resonant frequency is lower than expected See LD for a sample error. Wed Dec 1 18:17:05 2004 Error: 260118212 Host: orp Process: orp_subsys File: gen_exec.c Line: 2148 Wed Dec 1 18:17:04 2004 Host : Jedi Ermes # : 260118212 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2148 Function : No System Function Reported Scan Type : Helical Scan: 1375/2/1 (60-0314)ILR Current time out. The current resonant frequency is lower than expected. Error: 260105058 : (20-0269)
Applies to
- Models
- Discovery
- Product
- Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5332530 SC-Fast KV HV Tank for Discovery HD- Use after option upgrade ONLY See long description for details Part #: 5332530 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: SC-Fast KV HV Tank FRU: Yes Status: Orderable Comments: ** FE ASSIST ** Be sure you have SW version 09MW29.14. If you have SW version 08MW39.4 then you must order 5173970-2 SC HIGH VOLTAGE TANK. (212001147 010510) *** 2ND OPINION NOTES *** As of 02/11/10 Call Engineering Contact John Breunissen - 414-202-9485 or Daniel Nunez - 414-721-8460 Before ordering. Also, perform: Meter verification, No load test with/without tube, Focal spot diagnostics(with/without kV), and Filament heating diagnostic. If any of these tests fail without tube connected, replace the tank and redo the tests. Per HDVCT Options RSPL, 212008898, 5/4/09. 2ND OPINION NOTES *** Before ordering HV Tank perform: Meter verification, No load test with/without tube, Focal spot diagnostics(with/without kV), and Filament heating diagnostic. If any of these tests fail without tube connected, replace the tank and redo the tests. D3701T : PERSEUS TUBE UNIT - Used on CT750 HD See Long Description for details. Part #: D3701T Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: PERSEUS TUBE UNIT (GREEN) FRU: Yes Status: Orderable Comments: Per HDVCT RSPL, 212008898, 8/19/08. ** FE ASSIST ** Important to have adequate HV oil in the HV Wells. Making sure some oil does overflow when inserting Candle stick. (212001261 4/6/09)
- Area
- CT
Full cause & step-by-step resolution