GE Healthcare · MRDiscovery22676113577157
The RF Hub reports that there is no LO signal on the cable from the exciter/clock ref module to the RF Hub control board…
The RF Hub reports that there is no LO signal on the cable from the exciter/clock ref module to the RF Hub control board Due to the 3.0T RF Hub Control Board.
Symptom
Unable to Download or Reset the TPS MGD or ISE Unable to download TPS or ISE or MGD chassis
Error message
2267611 The RF Hub reports that there is no LO signal on the cable from the exciter/clock ref module to the RF Hub control board See Long Description Error - Tue Jul 14 02:32:39 2009 Error: 2267611 Host: C-3TMRI2 Process: diagCoord File: rfHub.cpp Line: 638 Diagnostic: RF Calib Iteration: 2 of infinite Action: 1 Task ID: 0x7f38530 Time: 3577157 Object: AGP Test Task Function: Software/Firmware/Config: N/A The RF Hub reports that there is no LO signal on the cable from the exciter/clock ref module to the RF Hub control board.-> Possible cause(s): NB DTx Module, RF Hub Control Board
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
- Component
- 5250098-2 3.0T RF HUB CONTROL BOARD 5250098-2 3.0T RF HUB CONTROL BOARD. Comments: MUST run all receiver diagnostics, including Coil Datapath Diagnostic, prior to placing order for this part. 212002950 October 24, 2008. Part is being set up for 3.0T DVMR program RSPL. 501139061, 5-Mar-08.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.