Pular para o conteúdo principal
GE Healthcare · MRDiscovery226741129917

Fails TPS Reset when booting up to Applications or when Resetting TPS due to Guided Install Does Not Reflect the Correct…

Fails TPS Reset when booting up to Applications or when Resetting TPS due to Guided Install Does Not Reflect the Correct Spectro Amp State After Upgrade to 20.1_IB1 Software due to a Software Problem.

Symptom

Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.

Error message

2267411 NO DTX2 MODULE FOUND. The IRF3 board does not see a broadband DTX2 module connected to it by dual fiber cable. MNS will not work without the DTX2 module present.-> See Long Description Error: 2267411 Host: MR3T Process: diagCoord File: Irf3.cpp Line: 2295 Task ID: 0x4940290 Time: 29917 Object: AGP Exception Class: Notification Function: Software/Firmware/Config: N/A NO DTX2 MODULE FOUND. The IRF3 board does not see a broadband DTX2 module connected to it by dual fiber cable. MNS will not work without the DTX2 module present.-> Extended Error: Verify that the DTX2 (broadband exciter) in the penetration cabinet is powered up and connected to the IRF3 board in the CAM chassis with a dual fiber cable. The DTX2 must be connected to a clock source on the DTX1 by a clock cable.

Applies to

Models
Discovery
Product
Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
Software
20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare MR issues