Customer is unable to scan due to intermittent PDU PS1 48V power supply failures.
Symptom
Unable to scan
Error message
2269060 The 1-Wire Network did not detect XGD GMC Power. Error: 2269060Host: PHSRADMR02 Process: diagCoord File: oneWire.c Line: 1143 Task ID: 0x6db4420 Time: 19823 Object: AGPException Class: NotificationFunction: Software/Firmware/Config: N/AThe 1-Wire Network did not detect XGD GMC Power 2267600 - The IRF3 detected a fault on the fiber links. Status register See Long Description Error: 2267600 Host: LIBR-MR1 Process: NSP File: AGP:Irf3RrfHWO Line: 1418 Exception Class: Unknown Severity: Unknown The IRF3 detected a fault on the fiber links. Status register=0x%X The modules connected to these IRF3 jacks were determined to be the cause of the disruption: %s Extended Error: A momentary problem with any module connected to the DVMR dual fiber links can bring the links down for every node. The IRF3 can detect which link was the first to drop out. The module connected to that link should be the one who initiated the problem. If several modules dropped out at the same time the IRF3 will report multiple modules. In this case there might be a single problem effecting multiple modules such as a power supply glitch or a drop out on the shared reference clock source. Note: a problem on the
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.0 Also called DVMR. This software is compatible with 3.0T Signa MR750 systems only
- Component
- 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109. Part is being set up for 3.0T DVMR program RSPL. 501139061, 5-Mar-08.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.