GE Healthcare · MRDiscovery222755622690572252239226905822691132269055
Fails TPS Reset when booting up to Applications or when Resetting TPS Due to failed Scan Room Power Supply.
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2227556 *** Reset/Download TPS was not successful. *** 2227556 sdm sdm_main.c 320 *** Reset/Download TPS was not successful. *** 2269057 The 1-Wire Network did not detect light on the DVMR Fiber Optic Link between the Exciter and the IRF3 Board. Error: 2269057 Host: andys3T Process: diagCoord File: oneWire.c Line: 1098 Task ID: 0x6db4420 Time: 4251 Object: AGP The 1-Wire Network did not detect light on the DVMR Fiber Optic Link between the Exciter and the IRF3 Board. 2252239 Startup Timeout was detected on the RF Hub. Fri Feb 27 07:06:41 2009 Error: 2252239 Host: mr1 heri Process: NSP File: SCP:CanAutoConfig Line: 3377 Exception Class: Unknown Severity: Unknown Function: Peripherals: Communications PSD: Unknown Coil: Unknown Scan: -1/-1 Startup Timeout was detected on the RF Hub.- 2269058 The 1-Wire Network did not detect Clock Reference 12V Power 2269058 Task ID: 0x6db4420 Time: 4251 Object: AGPException Class: Notification Function: Software/Firmware/Config: N/A The 1-Wire Network did not detect Clock Reference 12V Power.-> 2269113 The 1-Wire Network did not detect communication on the DVMR Fiber Optic Link between the MNS Exciter and the IRF3 Board 2269113 The 1-Wire Network
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.0 Also called DVMR. This software is compatible with 3.0T Signa MR750 systems only
- Component
- 5231801-3 Scan Room Power Supply 16 ch and 32 ch 5231801-3 Scan Room Power Supply, 16 ch and 32 ch
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.