Intermittently Unable to Scan due to Error Codes 2261713 Heat Exchanger Cabinet (HEC) detected the gradient coil coolant…
Intermittently Unable to Scan due to Error Codes 2261713 Heat Exchanger Cabinet (HEC) detected the gradient coil coolant flow is too high and 2268904 RF air temperature warning detected due to Custome…
Symptom
Intermittently Unable to Scan due to Error Codes 2261713 Heat Exchanger Cabinet (HEC) detected the gradient coil coolant flow is too high and 2268904 RF air temperature warning detected See Long Description Intermittently unable to scan due to error codes 2261713 Heat Exchanger Cabinet (HEC) detected the gradient coil coolant flow is too high and 2268904 RF air temperature warning detected 2261713 Heat Exchanger Cabinet (HEC) detected the gradient coil coolant flow is too high 2268904 RF air temperature warning detected. Future scanning will be inhibited until RF air temperature matches expected. 2268906 - RF coil air temperature is now at the requested level.
Error message
2261713 Heat Exchanger Cabinet (HEC) detected the gradient coil coolant flow is too high See Long Description 2261713 NSP SCP:CoolingHWO 2957 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: Probe-P Coil: HDNV Spectro Scan: 50252/13 Heat Exchanger Cabinet (HEC) detected the gradient coil coolant flow is too high. This alarm will not stop scanning-> Extended Error: Check the gradient coil coolant pressure sensor. 2268906 RF coil air temperature is now at the requested level. 2268904 RF air temperature warning detected. Future scanning will be inhibited until RF air temperature matches expected. See Long Description Thu Jan 15 14:56:24 2009 Error: 2268904 Host: signa2 Process: NSP File: SCP:SriCanHWO Line: 2030 Exception Class: Unknown Severity: Unknown Function: Patient Handling: Control/Display PSD: Gradient Echo Coil: HEAD Scan: 50171/1 RF air temperature warning detected. Future scanning will be inhibited until RF air temperature matches expected. Temperature difference: 20 0.1 degrees C Tolerance: 20 0.1 degrees C-> Extended Error The Heat Exchanger (HEC) manages RF coil air temperature. This message indicates that the HEC was unable to a
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.0 Also called DVMR. This software is compatible with 3.0T Signa MR750 systems only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.