Graphic Prescription Intermittently Crashes due to Host Computer.
Symptom
Graphic Prescription Intermittently Crashes See Long Description Discovery MR750 system is experiencing loss of graphics server several times a week. The scenario is that the operator starts a new exam, then starts a scan, and while system is scanning the operator clicks on image viewer, then clicks back on current patient, then as soon as the next series is clicked on to set up graphic Rx the system reports error “Communication with the Graphics server lost, GraphicRx will be closed. Please re-open Graphic Rx to continue prescription”. This is a popup message that isn't logged (see photo, below). At this point the operator can not get the graphics to fill the blank graphic window. Error code 2219864 is logged multiple times in the message log (see photo, below). The only fix the operator can do is to end the exam and start a new exam which may or may not recover the graphics server function. There is a 50/50 chance that this will work. If it doesn't work they have to reboot the system. Rebooting the system typically is the only option to recover the graphics server. iTrak # 13281575 CSO # 1-2051353365
Error message
2219864 An internal error occured in List/Select function at 3PLANE GRx Communication with the Graphics server lost, GraphicRx will be closed. Please re-open Graphic Rx to continue prescription See Long Description This error message appears to the operator in the form of a popup window (see below), the error is not logged on the system.
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.0 Also called DVMR. This software is compatible with 3.0T Signa MR750 systems only
- Component
- 5183547-30 MR DVMR Host HP 8400 5183547-30 MR DVMR Host HP 8400
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.