GE Healthcare · MR2252301
2252301 Multicoil Bias Fault Detected Open Circuit due to 0.7T Extremity coil Large Knee Array.
Symptom
Unable to Scan With Multi Coil Bias Faults Unable to scan with Multi Coil Bias Faults
Error message
2252301 Multicoil Bias Fault Detected - Open Circuit. Try re-seating all coil connectors. MCDx Channel x of y, counting from 1 Value x mA Limit y mA See Long Description for Extended Error 2252301 MRI_GB_OW0 NSP SCP:DCB 816 Multicoil Bias Fault Detected - Open Circuit. Try re-seating all coil connectors. MCD1 (or MCD2) Channel 1 of 16, counting from 1 Value: 2 mA Limit: 298 mA Mask of failed channels: 0x1 Ch 1-8 : Legacy MC Conn Ch 17-24 : Conn A Ch 25-32 : Conn B-> Extended Error: This fault was detected by the Driver Module. An open circuit fault occurs when the actual value is less than the pre-defined limit. Check system cables, connectors, coils and configurations. Re-seat all coil connectors. The mask of all failed channels indicates additional channels with the same fault - convert the hex number to a bitmap to decipher the mask, with channel 1 indicated by the least significant bit and channel 16 indicated by the most significant bit. For example, a mask of 0x3c converts to 0011 1100, meaning channels 3, 4, 5, and 6 all experienced the same failure. The key at the bottom of the error message shows the MC driver bias channels provided by the Driver Module used with each mult
Applies to
- Product
- Open Speed with EXCITE For HFO4 and HFO5 only
- Software
- OPENMR4-HFO4 Software version for HFO4 system, which is OpenSpeed with Excite Technology
- Component
- 2264742-2 0.7T EXTREMITY COIL LARGE KNEE ARRAY See long description 2264742-2 0.7T EXTREMITY COIL LARGE KNEE ARRAY This part has been identified as one requiring second opinion approval before ordering due to one or more of the following reasons. It is in critical short supply. Please troubleshoot before ordering this coil to help preserve stock. At minimum you should run the Multi-Coil Quality Assurance/SNR and MCR procedures and confirm failing results before ordering this coil. Utilize support resources at the OLC and in your Zone if needed to assist in troubleshooting. 212002950 06/20/2007
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Multicoil Bias Fault errors on multiple coils.
- Driver Module Errors Due to the MRID 1.5T 8 Channel NV Array Coil.
- Open Circuit due to Loose Hardware in Coil Cable's Hypertronics Connector.
- Multicoil Bias Fault Detected on Peripheral Vascular Coil Due to a Coil Segment Disconnected.
- Multi Coil Bias Faults Due to Bent Pins in Connector.
- 2252301 Multicoil Bias Faults Due to Coil.