GE Healthcare · CTDiscovery200002372200002355290009035
LightSpeed/Discovery CT750 HD
Symptom
Applications software fails to boot up completely and automatically shuts itself back down. Applications software fails to boot up completely and automatically shuts itself back down
Error message
Error: 200002372 An unexpected termination of verb_init caused operator notification of its demis See Long Description for complete error. Error: 200002372 An unexpected termination of verb_init caused operator notification of its demis Wed Dec 24 09:20:06 2008 Error: 200002372 Host: IHDMILHCT2 Process: cupMonitor File: ssProcStart.c Line: 856 The process verb_init took too long to start up. Wed Dec 24 09:20:06 2008 Error: 200002355 Host: IHDMILHCT2 Process: cupMonitor File: ssProcStop.c Line: 971 An unexpected termination of verb_init caused operator notification of its demis e. Error: 200002372 The process asir took too long to start up. See Long Description for complete error. Error: 200002372 The process asir took too long to start up. Wed Dec 24 09:21:04 2008 Error: 200002372 Host: IHDMILHCT2 Process: cupMonitor File: ssProcStart.c Line: 856 The process asir took too long to start up. Error: 290009035 Timeout waiting for ASIR process to connect. Creating images with Slice ASIR. See Long Description for complete error. Error: 290009035 Timeout waiting for ASIR process to connect. Creating images with Slice ASIR. Wed Dec 24 09:20:34 2008 Error: 290009035 Host: darc Process: re
Applies to
- Models
- Discovery
- Product
- Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5255299-30 - VRB - pronounced VeRB - Volume Reconstruction Box - USED on GOC6 Console - CT750 HD See Long Description for Details. 5255299-30 - VRB - pronounced VeRB - Volume Reconstruction Box - USED on GOC6 Console - CT750 HD Part #: 5255299-30 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: VRB - pronounced VeRB - Volume Reconstruction Box FRU: Yes Status: Orderable
- Area
- CT
Full cause & step-by-step resolution