GE Healthcare · MRDiscovery2252303
Using an Old Revision Six 6-Channel Grafidy3 Tool.
Symptom
Unable to Scan Grafidy3 With 2252303 Multicoil Bias Fault Detected Short Circuit Channel 7 of 16 See Long Description Unable to scan using the 6-Channel Grafidy3 Tool due to error 2252303 "Multicoil Bias Fault Detected - Short Circuit channel 7 of 16, counting from 1". This error isn't logged for any other coil on the system.
Error message
2252303 Multicoil Bias Fault Detected, Short Circuit. Channel X of Y See Long Description Error: 2252303 Host: lx-mr Process: NSP File: SCP:DCB Line: 1030 Multicoil Bias Fault Detected - Short Circuit. Try re-seating all coil connectors. MCD1 Channel 3 of 16, counting from 1 Value: -310 mA Limit: -301 mA Mask of failed channels: 0x3c Ch 1-8 : Legacy MC Conn Ch 17-24 : Conn A Ch 25-32 : Conn B-> Extended Error: This fault was detected by the Driver Module. A short circuit fault occurs when the actual value is more negative than the pre-defined limit. This could be caused by a shorted diode in the coil or a short elsewhere in the system. Check coil, system cables, connectors and configurations. The mask of all failed channels indicates additional channels with the same fault - convert the hex number to a bitmap to decipher the mask, with channel 1 indicated by the least significant bit and channel 16 indicated by the most significant bit. For example, a mask of 0x3c converts to 0011 1100, meaning channels 3, 4, 5, and 6 all experienced the same failure. The key at the bottom of the error message shows the MC driver bias channels provided by the Driver Module used with each multicoil
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.0 Also called DVMR. This software is compatible with 3.0T Signa MR750 systems only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.