GE Healthcare · CT17861210010178526182013230023002244640
Lightspeed 1.X - Octane
Symptom
Cannot perform tube warmup. Cannot perform tube warmup
Error message
Error: 178612 A certified mail request to the firmware failed See LD Mon Oct 6 07:06:08 2008 Error: 178612 Host: ct02_sbc Process: fwmgr File: CF.c Line: 1088 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 A certified mail request to the firmware failed. FW Requst: 10010 FW UUID: 230 Error: 178526 Scan Seq Id: 0 Write to mailbox with uuid 230 failed with return status 2103 See LD Mon Oct 6 07:06:08 2008 Error: 178526 Host: ct02_sbc Process: fwmgr File: CF.c Line: 900 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Write to mailbox with uuid 230 failed with return status 2103 Error: 182013 Logging soft exception watchdog time-out See LD Mon Oct 6 07:03:05 2008 Error: 182013 Host: ETC Process: Local Exc Handler File: exl_logging.c Line: 281 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Sec/Soft Time: 07:03:04:995 Log Series: 30 Logging soft exception watchdog time-out Error : 230023002 Scanner Hardware is not ready or unavailable See LD for more info Fri Jun 10 08:22:33 2005 230023002 4 cr_ct_01 scanUtilsRx DetailedCalUtils.c 1160 FAILED to execute the Scan Request. Possible
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required