GE Healthcare · X-ray VascularAdvantx667523324784389516850528611761
AdxE: 3D calibration failed AdxE: 3D calibration failed.
3D calibration failed
Symptom
AdxE: 3D calibration failed AdxE: 3D calibration failed. More details in Long description. 3D calibration failed. Typical images below (grid and helix). Helix calibration processing fails and calibration of first grid (largest FOV) fails too due to excessive distorsion on the gridwires. .
Error message
AdxE: Calib ! Status received : WARNING : : image x,Residual is too large for bullet 16 (value : 8.66752, tolerance : 5) followed by Calib ! Status received : WARNING : : image x,Image x not processed. More info in long description. In 3DSpincalib.log file on AW, following errors can be seen when attempting to process helix sequences (example below is related to helix sequence acquired in FOV 40 cm ie LCA+ or LCALP+ system) Helix processing errors pattern Aug 18 2008 10:23:01 > Calib > 1 > Start process : /export/home/sdc/spin3d/bin/helbille, with : /export/home/sdc/spin3d/calib/prm/helixF40.prm Aug 18 2008 10:23:01 > Calib > 1 > Start process 1233 Aug 18 2008 10:23:03 > Calib ! Status received : WARNING : : image 1,Residual is too large for bullet 16 (value : 8.66752, tolerance : 5) Aug 18 2008 10:23:03 > Calib ! Status received : WARNING : : image 1,Image 1 not processed Aug 18 2008 10:23:05 > Calib ! Status received : WARNING : : image 2,Residual is too large for bullet 16 (value : 7.33247, tolerance : 5) Aug 18 2008 10:23:05 > Calib ! Status received : WARNING : : image 2,Image 2 not processed Aug 18 2008 10:23:06 > Calib ! Status received : WARNING : : image 3,Residual is too
Applies to
- Models
- Advantx
- Product
- Advantx E Monoplane Advantx E Systems advantx e, vamp Advantx E generator Systems
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.
- Intermittent Gantry Lockup usually occurred when bagging the Detector or Removing the patient from the table.
- Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.
- Omega, Can not move the table top in the lateral direction.
- The Advantx Console is Blank on boot of the system.
- Exabyte won't archive or eject